DASS Cooling System Integrity Assurance Equipment (DCSIAE)

REQUIREMENTS

Airbus Defence & Space (AD&S) GMBH required a series of tools and bespoke engineering jigs to be able to check the integrity of their Wing Tip Pod refrigeration pipework system.

What was delivered?

16 x complete DCSIAE Kits providing the following capabilities:

  • Port & Starboard Hose Support Brackets – Used to relieve the strain of the refrigeration hoses on the WTP couplers
  • Tool chest – This foam lined tool case contains all the tools required to remove and install the WTP cooler
  • Helium Leak Detector – Capable of detecting leaks as small as 1 x 10-6 mbar l/s
  • Cooler Jig – A purpose-built jig designed to hold and test the WTP cooler
  • Port & Starboard WTP Jigs – Bespoke manufactured jigs used in pace of the WTP cooler to enable operators to pressure test and vacuum dehydrate the system pipework
  • Pressure Reducing Box – A custom designed pressure reducing box consisting of a highly sensitive He/N2 Regulator and DPI 800 pressure gauge enabling operators to accurately pressure test and vacuum dehydrate the refrigeration system
  • Helium Regulator – Contained within its own Peli-case this regulator is used on the supply Helium cylinder

What were the benefits?

When AD&S experienced a leak on one of their aircraft our kit gave them the capability to split the refrigeration system down into component parts to be able to identify the source of the leak. Operators can begin with a simple oxygen free nitrogen pressure test and can move onto a more intrusive helium check if required.

This equipment has increased Eurofighter flying hours and has enabled AD&S to reject WTP Coolers at the delivery stage before fitment to the aircraft.

MORE CASE STUDIES

Inside the Cold Room: Oliver Jell

Another staff member to be interviewed in our Cold Room series: Oliver Jell. Oliver has worked at Lightfoot since 2019, he was initially brought in as a Senior Workshop Engineer to assist with the building and testing of the then new LIDSS ground equipment, since then he has been involved in a number of other Aerospace projects within Lightfoot.

Read More »
Greenstem high temperature heat pump

RTU/DVRU – Low pressure, high boiling point refrigerant recovery & transfer

The Lightfoot International Limited (LI) Refrigerant Transfer Unit (RTU) is a CE marked Refrigerant Transfer Unit which has been specifically designed to recover, transfer, or charge low pressure, high boiling point refrigerants such as R245fa and R1233zd (E), in a liquid or vapour state from any RACHP system.

The RTU can be used to charge/transfer refrigerant between clean systems or in support of a full system recovery operation when coupled directly into a DVRU (the RTU MUST be connected in line with the DVRU to carry out a full system recovery). This coupling of the RTU and DVRU will enable the complete Deep Vacuum Recovery of the RACHP system, and other types of specified refrigerants. The unit can be operated by one refrigeration engineer.

Read More »

Submit your CV